Electrochemical Sensors for the Measurement of Chlorine, Chlorine Dioxide, Ozone, Hydrogen Peroxide and Peracetic Acid

Russell Mainstream Supply Ltd

By William Russell, , Russell Mainstream Supply Ltd

With the exception of the 4-20mA sensors, where the length is 220mm, the sensors have a length of 175mm and a diameter of 25mm, with plug adaptor connection.

Electrochemical Sensors

They are designed to fit into the available flow cells. The low current produced by the sensors is electronically amplified in the measurement cell. No zero point calibration is necessary, and measurements can be taken in pressure up to 1 BAR.

The sensors are temperature compensated, and will operate in the range 0 to 45 degrees C (for the 7 Series, 0-55). The water has to be flowing to obtain a reading, which is why flow cells are recommended. Changes to the minimum flow rate will only slightly affect the measurement signal.

Surfactants should not be present in the water being measured (does not apply to the 7 Series probes). For the dual electrode system, the measurement cell is made of gold, and the counter and reference electrodes of silver with silver halogenid coating. A bias voltage (polarisation) is applied between the two electrodes.

For the potentiostatic 3 electrode system, the measurement electrode is made of gold, the reference electrode is made of silver with a silver halogenid coating, and the counter electrode of stainless steel.

Chlorine Amperometric Sensors

CL4.1 - Application: Free Chlorine, Inorganic Chlorine. Cannot measure with Cyanuric Acid present.
CS2.3 - Application: Free Chlorine, Organic & Inorganic Chlorine, Reduced pH Dependency
CC1 - Application: Total & Free Chlorine, Isocyanuric Chlorine, Reduced pH Dependency
CP2.1 - Application: Total & Free Chlorine, Organic & Inorganic Chlorine, Reduced pH Dependency

  • Amperometric Two and Three electrode systems with replacement membranes.
  • 30/40 L/h Flow rate required.
  • 1 Bar permissable pressure
  • Single point calibration
  • Sample must be free of surfactants

Specifications

For more information on 2-pole and 4-pole sensors, please click here.

  • Handling, commissioning and service are extremely easy. The electrode system has a very long working life, with just the membrane cap subject to wear and tear. This needs to be replaced every year. However, maintenance costs are very low.
  • The time needed to polarise most of the probes is less than 2 hours.
  • No zero point calibration is necessary, and it is only necessary to have a single point calibration, only a slope test is required.
  • Because the flow dependence is so low, various in-line probe housings can be used, and it is possible to fit "in-line".
  • For most of the probes it is possible to operate up to 1 Bar (higher on request), and this enables the water to be easily returned.
  • Temperature compensation is integrated in every probe.
  • 90% of the final value of the measurement can be reached in less than 2 minutes for most measurement probes.
  • Long term stability is excellent, slope loss is approximately 1% per month.
  • Due to low impedance of the probes, long cables can be used without problems.
  • Because the probes are available with different ranges, and power supplies, they
    can be used with a customers existing controllers.

If a suitable one is not available R.M.S Ltd are able to supply one.

Chlorine Dioxide, Ozone, Peracetic Acid & Hydrogen Peroxide
Amperometric Sensors.

  • Amperometirc Dual Electrode System with Replacement Membranes.
  • Severn Series for measurements when surfectants present.
  • Gold Cathode, Silver/Silver Halogenid Anode.
  • One and four series temperature range 45oC.
  • Severn series temperature range 55oC.

Specifications

For more information on 2-pole and 4-pole sensors, please click here.

ME5090 - Controller
Can be configured to: pH, Redox, Chlorine, Chlorine Dioxide, Ozone, Peracetic Acid, Hydrogen Peroxide or Temperature

ME5090 Controller connected up to the PEF1 Flow Through Cell
ME5090 Controller connected up to the PEF1 Flow Through Cell

Amperometric SensorDAS-CL

  • 1 x Amperometric Sensor
  • Up to 50oC Temperature
  • 6 x 8mm Hose Connector
  • Up to 5 Bar pressure
    (Requires installation kit)

 

Amp Sensor

PEF1

  • 1 x Amp Sensor
  • 6 Bar Pressure
  • Needle Valve & Flow Indicator
  • Stop Flow Switch

Amp Sensor

PEF3

  • 1 x Amp Sensor & 2 x PG13.5
  • 6 Bar Pressure
  • Needle Valve & Flow Indicator
  • Stop Flow Switch

Amp Sensor
PEF5

  • 2 x Amp Sensors & 3 x PG13.5
  • 6 Bar Pressure
  • Needle Valve & Flow Indicator
  • Stop Flow Switch

or an order form or for information on electrochemical sensorsand related accessories from Russell Mainstream Supply Limited, please click here.

For further information on disinfection probes, please clickhere.